14 kVA Kohler Three Phase Multi Process DC Arc Welder Generator_Manual

13/11/14 M38_EN
ENGLISH
ENGLISH
M
38.13
REMOTE CONTROL
SERIE EVO / EVO MULTI4
RC2 - RCE - RCE/PL
REV.0-04/21
The remote control for adjusting the welding current or voltage
must be connected to the front panel of the machine with a
multiple connector.
When the remote control is connected to the remote control
connector (8), it is functional and automatically excludes the
front panel regulation. The remote control can also be con-
nected to the connector on the wire feeder front panel but in
this case it is necessary to switch the wire feeder commutator
so it can operate.
The remote control of the polarity inverter (64) allows you to
change the polarity directly from the control itself.
Move the regulator knob in correspondence of the selected cur-
rent or voltage value in order to obtain the necessary amperage,
keeping in mind the diameter and type of electrode and wire.
8
64
POLARITY SWITCH
POLARITY SWITCH
8
RC2 - RCE RCE/PL
ENGINE DRIVEN
WELDER
REMOTE CONTROL
FUNCTION
REMOTE
CONTROL
MODEL
TS EVO
TS EVO INSTRUMENTS
Welding current
adjustment
RC2
TS EVO MULTI4 Welding current
adjustment
RCE
TS EVO INSTRUMENTS
TS EVO MULTI4
Welding current regula-
tion and polarity change
command
RCE/PL
ATTENTION
When the RC is not used, it is necessary to disconnect the
multipole connector
!
PUSH AND
SCREW TIGHT
PUSH AND
SCREW TIGHT
34