Product Manual
TS 200 DES/EL
© MOSA REV.0-11/06
M
1.5Technical Data
30/11/06 27292-GB
The TS 200 engine driven welder ia a unit which ensures the function as:
a) a current source for are welding
b) a current source for the auxiliary generation
Unit meant for industrial and professional use, powered by an endothermic engine; it is composed of various main parts such
as: engine, alternator, electric and electronic controls, the fairing or a protective structure.
The assembling is made on a steel structure, on which are provided elastic support which must damp the vibrations and also
eliminate sounds which would produce noise.
Technical data TS 200 DES/EL
D.C. WELDING C.C.
Duty cycle 170A/60% - 130A/100%
Welding current regulation (I scale) 20 - 170A
Welding voltage 65V
GENERATOR
Three-phase generation 6 kVA / 400 V / 8.7 A
Single-phase generation 5 kVA / 230 V / 21.7 A
Single-phase generation 2.5 kVA / 110 V / 22.7 A
Single-phase generation 2 kVA / 48 V / 41.6 A
Frequency 50 Hz
Cos
ϕϕ
ϕϕ
ϕ 0.8
ALTERNATOR Self-excited, self-regulated
Type three-phase, asynchronous
Insulating class H
ENGINE
Mark / Model Yanmar / L 100 N
Type / Cooling system 4-Stroke / air
Cylinders / Displacement 1 / 435 cm
3
Output 6.5 kW (8.8 HP)
Speed 3000 rpm
Fuel / Fuel consumption Diesel / 254 g/kWh
Engine oil capacity 1.6 l
Starter electric
GENERAL SPECIFICATIONS
Tank capacity 5.5 l
Running time 4.5 h
Protection IP 23
Dimensions Lxwxh (mm) * 900x550x622
Weight * 133 Kg
Rumorosità 99 LWA (74 dB(A) - 7 m)
* Dimensions and weight are inclusive of all parts without wheels and towbar CTM.
POWER
Declared power according to ISO 3046-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
It’s admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up
to the end-user and under his direct responsibility to make a correct evaluation of the same risk and to adopt
specific precautions (for instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level (LWA)
- Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time.
This is not submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its
value changes in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic
Noise Level (LWA)
of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A) Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A) Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE: the symbol when with acoustic noise values, indicates that the device respects noise
emission limits according to 2000/14/CE directive.
2000 / 14 / CE