Product Manual
USE AS WELDER TS 200 DES/EL
M
34
© MOSA REV.0-11/06
30/11/06 27292-GB
This symbol (Norm EN 60974-1 security
standards for arc welders) signifies that the
welder can be used in areas with increased risk of
electrical shock.
PUSH AND
TWIST
The welding sockets, after the machine is started
(see page M21), also with no cables, are anyway
under voltage.
ATTENTION
Check at the beginning of any work the electric
parameters and/or the control placed on the front.
Fully insert the welding cable plugs into the
corresponding sockets turning them clockwise to
lock them in position.
☞
Make sure that the ground clamp ,whose cable
must be connected to the + or - terminal,
depending on the type of electrode, makes a
good connection and is near to the welding
position.
Pay attention to the two polarities of the welding
circuit, which must not come in electric contact
between themselves.
REMOTE CONTROL TC…
See page M 38
To reduce the risk of electromagnetic
interferences, use the minimum lenght of welding
cables and keep them near and down (ex. on the
floor).
The welding operations must take place far from
any sensitive electronic device.Make sure that
the unit is earthed (see M20). In case the
interference should last, adapt further
disposition,such as: move the unit, use screened
cables, line filters, screen the entire work area.
In case the above mentioned operations are non
sufficient, please contact our Technical
Assistance Service.
ATTENTION
With a welding cable length up to 20 m is
suggested a section of 35 mm²; wìth longer
cables a bigger section is required.
CAUTION
WELDING CURRENT REGULATION
Position knob (T) in correspondance of the chosen
current value, so as to obtain the
necessary amperage, taking into
acount the diameter and the type
of the electrode.
For technical data see page M52.
Protection fuse:
the fuse protects the electronic welding
PCB in case the remote control is short
circuited.