Product Manual
MAGIC WELD 200 YD - YDE
M
22
REV.0-02/14
STOPPING
+Before stopping the engine it is compulsory to stop the load:
- stop welding;
- shut off any loads which are connected to the unit auxiliary
outputs.
RECOIL VERSION
Let the motor run at no load for several
minutes to allow for cooling and then move
the accelerator control into the “STOP”
position.
ELECTRIC STARTING
Wait for the motor to automatically go to
the minimum RPM, 6/7 seconds after load
release, leave the motor running under the-
se conditions for several minutes in order to
allow for cooling, then turn the starting key
to the “OFF” position.
OFF
ON
START
To switch off the motor in case of emergency, either move
the accelerator control to the “STOP” position immediately or
move the starter key to the “ON” position.
ATTENTION
!
Shut the fuel cock.
+NB.: for safety purposes remove the starter key from
the machine at the end of every work session.
20/02/14 22270-GB