Product Manual

MAGIC WELD 200 YD - YDE
M
21
REV.0-02/14
STARTING
Check daily
RECOIL VERSION
1) Open fuel cock
2) Accelerator lever must be in the
"START” position.
3) Grasp the starter handle as
shown
4) Pull the starter rope until you feel
resistance and let it return slowly
to its original position
5) lower the decompression lever
1) Carry out operations 1) and 5) as with pull start
2) Turn the starter key to the “ON” position, the accelerator
control solenoid will automatically move the
accelerator lever into the "START" position
3) Turn the starter key to the “ON” position, when the
motor is running, let the key reposition itself to "ON"
4) When the motor is started, it will immediately reach
the nominal RPM for approx. 6/7 seconds, after which
time it will automatically go down to the minimum set
by the solenoid which controls the accelerator lever.
5) When welding power or auxiliary generation is required,
the motor will automatically go up to the nominal RPM
necessary for the use of the machine.
EMERGENCY PULL START
FOR ELECTRIC STARTER VERSIONS
If all the above conditions have been met, proceed as
follows:
ELECTRIC STARTING
OFF
ON
START
The pull start, for electric starter versions, is only possi-
ble if the all the conditions listed below have been met:
- the starter battery must remain connected to the
electrical circuit;
- the starter battery must be able to power the accele-
rator control solenoid, check this condition turning the
starter key to the “ON” position;
- unplug the pressure switch cable.
WARNING
!
1) Open fuel cock
2) Turn the starter key into the “ON” position, check that
the accelerator control solenoid moves the accelerator
lever into the “START” position
3) Grasp the starter handle as shown
4) Pull the starter rope until you feel resistance and let it
return slowly to its original position
5) lower the decompression lever
6) pull the rope rmly as far as it will go. If necessary use
two hands.
6) pull the rope rmly as far as it will
go. If necessary use two hands
20/02/14 22270-GB
NOTE
Do not alter the primary conditions of regulation and do
not touch the sealed parts.
!