Product Manual

20/02/14 22270-GB
Technical data MAGIC WELD 200 YD - YDE
M
1.5
REV.0-02/14
I
GB
F
Technical data MAGIC WELD 200 YD MAGIC WELD 200 YDE
A.C. GENERATION 50/60 Hz
Single-phase output 230V (max) 3.3 kVA / 230 V / 14.3 A
Single-phase output 230V (continuous) 3 kVA / 230 V / 13 A
Single-phase output 115V (max) 2.1 kVA / 110 V / 18.3A
Single-phase output 115V (continuous) 1.8 kVA / 110 V / 16.4 A
Cos ϕ
0.8
ALTERNATOR
Type permanent magnet, self-excited, brushless
Insulating class H
ENGINE
Mark / Model YANMAR L70N
Type / Cooling system Diesel 4-stroke / Air
Cylinders / Displacement 1 / 320 cm
3
Net power 4.9 kW (6.7 HP)
Speed 3600 rpm
Fuel consumption (Welding 60%) 1 l/h
Engine oil capacity 1.05 l
Starter recoil Electric
GENERAL SPECIFICATIONS
Tank capacity 3.3 l
Running time (Welding 60%) 3.3 h
Protection IP 23
Dimensions max. on base Lxlxh * 630x480x540
*Weight (dry) 72 Kg 91 Kg
Acoustic power LwA (pressure LpA) 103 dB(A) (78 dB(A) @ 7 m)
* Dimensions and weight are inclusive of all parts.
POWER
Declared power according to ISO 3046-1 (temperature 25°C, 30% relative hummidity, altitude 100 m above sea level).
It’s admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specic precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level
(LWA) - Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(LWA) of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A) Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A) Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE: the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.
2000 / 14 / CE