Installation Requirements
Inlet - Outlet Plumbing Options
Always install either a single bypass valve (provided)
to the contractor/plumber-supplied plumbing, as shown
in Figure 7 OR if desired, a 3 valve bypass system
(parts not included) can be installed, as shown in
Figure 6. Bypass valves allow you to turn off water to
the Whole Home Water Filtration System for mainte-
nance if needed, but still have water in house pipes.
Use either:
Copper pipe
Threaded pipe
PEX (Crosslinked Polyethylene) pipe
CPVC plastic pipe
Other pipe approved for use with potable water
IMPORTANT: Do not solder with plumbing attached to
installation adapters and single valve
bypass. Soldering heat will damage the
adapters and valve.
FIG. 7
FIG. 6
3 Valve Bypass
Whole Home Water
Filtration System
INLET
Connecting Plumbing to Valve
2 of each
included
1” NPT
Adapter
Clip
1” NPT Sweat
Adapter (2)
(not included)
Use teflon tape,
pipe joint com-
pound or both
Bypass
Valve
Valve
Inlet
INOUT
INOUT
Use teflon tape,
pipe joint com-
pound or both
Clip
Valve
Inlet
1” NPT
Adapter
2 of each
included
1” NPT Sweat
Adapter (2)
(not included)
Cross Over
FIG. 5
To Whole Home
Water Filtration System
Main Water Pipe
In what direction does the water flow?
Be sure to plan piping so water flow is to the
Whole Home Water Filtration System valve IN-
LET. Plan a crossover if flow is from left to right.
Treated
Water from
Valve
OUTLET
Whole Home Water
Filtration System
OUTLET
Untreated
Water to
Valve
INLET