Specifications

Morton
®
Installation & Operation Manual 17
Troubleshooting
FIG. 23
Removing Drain Fitting to
Clean Flow Control
Cleaning the Drain Flow Control
This procedure is not required if the Whole Home
Water Filtration System is operating normally. It
should be performed only if a problem with lack of
water flow to drain is encountered, as detailed in the
troubleshooting table on Page 16.
1. Remove the clip holding the drain fitting into the
valve (See Figure 23).
2. Remove the drain fitting from the valve
3. Clear any obstruction.
4. Reinstall the drain fitting into the valve.
5. Reinstall the clip to secure the drain fitting in the
valve.
PROBLEM CAUSE CORRECTION
Water running to the
drain (while unit is not in
the Clean Rinse cycle)
Inner valve defect causing leak Replace seals and rotor
Filter media in household
plumbing
Crack in distributor or riser tube Replace distributor or riser tube.
Procedure for removing error code from display:
1. Unplug transformer from electrical outlet.
2. Correct problem.
3. Plug in transformer.
4. Wait 6 minutes. The error code will return if the problem was not corrected.
Assistance from customer service may be needed with the following:
Need help troubleshooting? Call Toll Free 1-888-64 WATER (1-888-649-2837)
Monday- Friday, 8 AM - 9 PM EST or visit www.systemsaver.com
When you call, please be prepared to provide the model, date code and serial number,
located on the rating decal on back of the cover.
Clip
Hose
Clamp
Drain
Hose
Flow
Control
Drain
Fitting