Specifications

Morton
®
Installation & Operation Manual 13
Customizing Features / Options
Set Number of Days Between Clean
Rinse Cycles
By default the Whole Home Water Filtration System
will automatically initiate a Clean Rinse every 14
days. This should be sufficient for most applications.
To change the number of days between Clean Rinse
cycles:
1. Press the PROGRAM button until “RECHARGE” is
shown in the display.
2. Press the
UP or DOWN buttons to set the
number of days between Clean Rinse cycles (from 1
to 99).
3. Press the PROGRAM button again when com-
plete.
Set Clean Rinse Time
By default the Whole Home Water Filtration System
will Clean Rinse at 1:00 a.m.
To change the Clean Rinse start time:
1. Press the PROGRAM button until “RECHARGE
TIME” is shown in the display.
FIG. 14
2. Press the UP or DOWN buttons to set the
Clean Rinse time. Be sure AM or PM is correct.
3. Press the PROGRAM button again when com-
plete.
FIG. 15
Set Length of Clean Rinse
By default the Whole Home Water Filtration System’s
Clean Rinse cycle will consist of a 2 minute back-
wash followed by a 1 minute fast rinse. This should
be sufficient for most applications.
Increasing the length of Clean Rinse time will
increase the amount of water flushed to drain during
each Clean Rinse cycle, therefore, these times
should only be increased when necessary.
To change the length of the backwash part of the
Clean Rinse cycle:
1. Press and hold
the PROGRAM button for a few
seconds, until the “000--” screen appears, as shown
in Figure 16.
2. Press the PROGRAM button once, so “bA TIME”
appears in the display.
FIG. 16
3. Press the UP or DOWN buttons to set the
length of backwash in minutes.
4. Press the PROGRAM button again when com-
plete.
To change the length of the fast rinse part of the
Clean Rinse cycle:
1. Press and hold
the PROGRAM button for a few
seconds, until the “000--” screen appears, as shown
in Figure 16.
2. Press the PROGRAM button twice, so “Fr TIME”
appears in the display.
3. Press the
UP or DOWN buttons to set the
length of fast rinse in minutes.
4. Press the PROGRAM button again when com-
plete.
FIG. 17