Specifications

50--3/8”
41--5/8”
INLET
OUT
INLET -- OUTLET
14”
3-- 7/8
18--1/4”
6
Mortonr System Saverr Installation & Operation Manual
SPECIFICATIONS / DIMENSIONS
MODEL MSD45E
RATED CAP ACITY (grains @ lbs salt dose) 13,300 @ 2.6
35,700 @ 9.9
45,400 @ 17.2
RA TED EFFICIENCY (grains / lb @ min. salt dose) H 5120 @ 2.6
AMOUNT OF HIGH CAPACITY RESIN (lbs / cu ft) 65.5 / 1.26
RESIN TANK NOMINAL SIZE (in., dia x height) 10 x 40
SERVICEFLOWRATE(gpm) 10.0
PRESSURE DROP AT SERVICE FLOW (psi) 11
INTERMITTENT FLOW RATE @ 15 psi (gpm) Y 12.3
WATER SUPPLY MAXIMUM HARDNES S (g pg) 120
W ATER SUPPLY MAX. CLEAR WATER IRON (ppm) D 12
WATER PRESSURE LIMITS (min. / max. psi) z 20 --- 125
WATER TEMPERATURE LIMITS (_F) 40 --- 120
WATER SUPPLY MINIMUM FL OW RATE (gpm) 3
REGENERATION CYCLE FLOW RA TES (gpm)
FILL ( flow to brine tank)
BRINING
BRINE RINSE
MAX. BACKWASH
MAX. FAST RINSE
(flow to drain)
.3
0.22
0.15
2.0
2.0
This system conforms to NSF/ANSI 44 for specific performance claims as verified and substantiated by test data.
H Efficiency rating is only valid at the lowest salt dosage. These softeners were efficiency rated according to NSF/ANSI Standard 44.
Y Intermittent flow rate does not represent the maximum service flow rate used for determining the softeners rated capacity and efficien-
cy. Continuous operation at flow rates greater than the service flow rate may affect c apacity and efficiency performance.
D Capacity to reduce clear water iron is substantiated by WQA test data.
z Canada work ing pressure: 1.4 -- 7.0 kg/cm@.