Technical Data Bulletin

2002
Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine 04083
TEL: 800-252-2306; FAX: 207-490-2998; WEBSITE: www.advancedflashing.com
______________________________________________________________________________
***** Mortar Maze Weep Vents are provided in two sizes. *****
3. Size: [[3/8 by 2-1/2 by 3-3/8] [3/8 by 3-1/2 by 3-1/2] inches.] [[10 by 64 by
89] [10 by 89 by 89] mm].
***** Advanced Building Products, Inc. provides Mortar Maze Weep Vents in several
colors to match typical mortar colors. *****
4. Color: [Selected by Architect from manufacturer's full range.] [Match mortar
color.]
PART 3 - EXECUTION
3.1 INSTALLATION
A. Install weep vents as part of masonry wall construction and in accordance with
manufacturer's installation instructions. Coordinate with installation of through wall
flashings.
B. Locate weep vents at [wall bases, above door and window openings, above bond
beams, and other through wall flashings.] [At locations detailed on Drawings.] Space
at [_____] [inches] [mm] maximum.
C. Embed weep vents in vertical mortar head joints. Tool joints to prevent obstruction
of weep spouts.
END OF SECTION