Instructions
27
Be aware of the following:
Cleaning procedure: Discuss this with chimney sweep or qualied installer prior
to or during the stove installation.
Chimney draft: If the chimney draft is naturally poor it is better to install the ue from
the top of the stove so as to minimise any internal resistance of the ue gases.
Avoid having any more than 2 bends in the ue system and limit the length of the
oset between bends.
Fresh air supply
A wood-burning stove requires air for combustion. As a result, ring a wood-burn-
ing stove will help create a healthy climate in your house. If the house is very tightly
sealed, and particularly if there is a cooker hood or ventilation system in the house, it
may be necessary to install an air grate in the room in which the wood-burning stove
is installed. Otherwise there may not be enough draught in the chimney, which may
result in the stove not being able to burn properly, and smoke may come out of the
stove when the re door is opened. If it is necessary to install air grates, they must
be positioned so that they cannot be obstructed. The Morsø 7370/7470 stoves
only have the rear fresh air supply available.
Morsø 7470 wallmounted