Instructions

24
DK ENG
We recommend that the stove be installed at least 10 - 15 cm from masonry, in order to al-
low heat to circulate and to facilitate the cleaning of the inside and outside of the stove. A
layer of wallpaper on a brick wall is normally viewed as non-ammable material.
The oor
If the stove is installed on a ammable oor, national and local regulations must be observed
with regard to the size of the non-ammable underlying surface that must cover the oor be-
neath the stove. The underlying surface must naturally be able to bear the weight of the stove
and, if applicable, the steel chimney.
Distance to furniture
The minimum clearance to combustible materials in front of the stove is 850 mm. The mini-
mum distance to combustible materials must be observed; furthermore, it should be con-
sidered whether furniture and other items will dry out if placed near the stove.
A wood-burning stove gets hot when it is red. Caution must therefore be observed, par-
ticularly with regard to children touching the stove.
Minimum distance to combustible material - Morsø 7300
Installation Stove type Distance A Distance B Distance C Distance
front of
stove
Normal parallel Morsø 7300
uninsulated ue
200 mm 400 mm -
850 mm
Normal parallel Morsø 7300
insulated ue
100 mm 400 mm -
Corner Morsø 7300
uninsulated ue
- - 350 mm
Minimum distance to combustible material - Morsø 7400
Installation Stove type Distance A Distance B Distance C Distance
front of
stove
Normal parallel Morsø 7400
uninsulated ue
200 mm 450 mm -
850 mm
Normal parallel Morsø 7400
insulated ue
100 mm 450 mm -
Corner Morsø 7400
uninsulated ue
- - 350 mm