17. Sliding door - ball bearing guide
The ball bearing guide must be lubricated at lea-
st once a year. Push the door up into its topmost
position and apply the heat-resistance grease to
the rails in a thin layer (see arrows). ”Fin Grease”
can be used and other greases that can with-
stand the following temperature range:
-30 °C to 220 °C (if necessary ask your dealer).
18. What to do if...?
... the re is barely going or goes out by itself?
• Check that the air damper is open (if one is tted on the chimney).
• Check that the combustion air handle is open (+).
• Is your wood dry enough?
• Check whether the outdoor temperature is too high (>15C°)?
... the room doesn’t get warm enough?
• Check that the convection air grates are open.
• Check whether the draught in the chimney is too strong.
... the re is too strong and combustion uncontrollable?
• Check that the combustion air handle is in the correct position (+ / -).
• Check that the sealing cords on the inside of the door frame/glass are OK and not
damaged.
• Check that the door is closed properly.
• Check whether the draught in the chimney is too strong.
... the glass soots over too quickly?
• A small amount of soot on the glass after stoking for 8-10 hours is normal.
• Have you used dry and clean wood?
• Was the replace insert lit properly before turning down the combustion air?
19. What information does your installer/dealer need?
• If your replace inset develops a fault,
your installer will need the following data:
– Identity number and model name
– Original invoice (date of sale)
• You can nd the type plate under the
stone/cast-iron grille/ash box in the
combustion chamber.