1.6 Fluepipe connections
The stove comes standard with a ue collar (1) at the top and a cast-iron cover mounted on
the cast-iron back panel behind the convection back panels. If you want to install the stove
with a rear ue exit remove the knock out section of the convection back panel with steady
hammer taps to the small bridge which holds the knock out in place. Remove the ue collar
from the stove, unbolt the cast-iron cover from the back panel and install it in the top plate.
Centre the ue collar in the hole on the back side of the stove and bolt it securely in place
with the bolts and clamps provided.
Make sure that the bae plate (2), the re bricks and the
riddling are positioned correctly.