FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS ENCLOSURE MODEL 90566400 FOR INSERT MODEL 5660NA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD KEEP THESE INSTRUCTIONS FOR FUTURE USE These products have been tested and listed to the standards UL127-2009 and ULC-S610-M87 Morsø US LLC 1011 Hwy. 52 West Portland, TN 37148 TEL: (615) 323 0561 Report # 192-S-22-2/192-S-22b-2 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
Installing the Fireplace Insert Enclosure PRODUCT SAFETY THESE FIREPLACE INSERT ENCLOSURES ARE A LISTED COMPONENT FOR AND ARE INTENDED FOR USE WITH THE MORSØ MODELS 5660 STANDARD AND 5660NA WOODBURNING FIREPLACE INSERTS ONLY. DO NOT USE OTHER PRODUCTS NOT SPECIFIED OR LISTED FOR USE WITH THESE ENCLOSURES. WARNING: IF THESE ENCLOSURES AND FIREPLACE INSERTS ARE NOT PROPERLY IN- STALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE IN- STALLATION INSTRUCTIONS EXACTLY.
Installing the Fireplace Insert Enclosure SELECTING THE LOCATION FOR YOUR INSTALLATION This insulated metal fireplace insert enclosure enables the MORSØ MODEL 5660 STANDARD or MODEL 5660 NA Fireplace Insert to be installed in minimum–clearance situations in locations without an existing masonry fireplace. This could be in new home construction or in homes that are being remodeled. Centrally located installations generally provide and circulate the heat most effectively.
Installing the Fireplace Insert Enclosure CHIMNEY REQUIREMENTS For proper draft and best performance, the chimney should extend at least 15‟ (4.6m) and not more than 35‟ (10.6m) above the level of the MORSØ Model 5660 STANDARD or Model 5660NA hearth. The chimney must be properly installed and supported in accordance with the chimney manufacturer‟s instructions. The enclosure is not intended to support the entire weight of the chimney. Support components are available from the chimney manufacturer.
Installing the Fireplace Insert Enclosure COMBUSTIBLE FRAMING The Morsø Fireplace Insert Enclosure is designed with spacers on the side and back surfaces that prevent the enclosure walls from coming in contact with adjacent combustible materials that are used for framing around the enclosure.
ELECTRICAL CONNECTIONS If you are installing the Model 5660 NA with the optional blower, you must have electrical power connected to the single outlet provided on the side of Enclosure Model 95066400. Refer to the National electrical Code, ANSI/NFPA 70 and other local code requirements. Use a licensed electrician. The electrical specifications are 120 VAC, 60Hz, less than 1 amp. OUTSIDE AIR If the Outside Air Kit is to be installed, remove the Outside Air Cover Plate from the rear of the enclosure.
Installing the Fireplace Insert Enclosure RECOMMENDED ROUGH FRAMING DIMENSIONS C B A FIG. 2 Framing Front View FIG. 3 Framing Side View A = 67” (1702mm) B = 39 3/4” (1010mm) C = 25 1/2” (648mm) Minimum B C Note: These dimension are for both Model 90566000 and Model 90566400 Enclosures FIG.
Installing the Fireplace Insert Enclosure MINIMUM CLEARANCES TO ADJACENT COMBUSTIBLE MATERIALS Combustible / Non-Combustible Material Limits E = 39 3/4” (1010mm) F = 67” (1702mm) G = 28 3/4” (730mm) J = 29 1/4” (742mm) Ceiling Model 5660 21 3/8” (543 mm) 16 3/8” (416mm) H K Model 5660NA 26 1/8 “ (664) 11 5/8” (295) E D Non-Combustible Materials Only J D = 67” (1702mm) Minimum F G H Top of enclosure support structure when enclosure is elevated off floor K FIG. 5 FIG. 6 FIG.
Installing the Fireplace Insert Enclosure HEARTH REQUIREMENTS When using the Insert in the Fireplace Insert Enclosure, the L = 39 3/4” (1010mm) Min. hearth protection requirements are different than when inM = 16” (405 mm) Min. USA stalling the Insert in an existing masonry fireplace. The en- N = 8” (203mm) Min. closure has been designed to elevate the insert to the minimum distance above the combustible floor where no thermal floor protection is required.
Installing the Fireplace Insert Enclosure CUSTOMIZING THE FINISHED APPEARANCE The facing of the Fireplace Insert Enclosure may be finished to give a variety of different aesthetic appearances. However, only non-combustible materials may be applied to the face inside the specified limits for combustible materials. See FIG. 6 on page 8. Outside the combustible limits, the any surface finish may be used.
Installing the Insert into the Enclosure Prepare the Insert Refer to the Morsø Installation and Operating Instructions for either Model 5660 NA Standard or 5669 NA with New Blower for instructions on how to prepare the insert for installation. Follow the Blower Installation instructions on page 14 if you are installing the Insert with the optional blower. Plug the blower power cord into the electrical outlet in the side of the enclosure. Route the power cord between the insert stand and the enclosure side.