Specifications

6
ENG
1.7 Connecting the stove to a masonry chimney
A wall sleeve should be bricked securely into the wall of the chimney at the appropriate height
and the stovepipe inserted centrally. The pipe must not extend into the actual chimney open-
ing, but rather must reach only to the inside of the chimney aperture. The gap between the
stovepipe and sleeve must be sealed using glass fibre packing rope.
Only use stovepipe components that comply to National and Local Building Regulations.
1.8 Connecting to a stainless steel insulated chimney system
If your installation involves taking the chimney straight up and through the ceiling, you must
comply with National, Local Building Regulations or flue manufacturers instructions concern-
ing clearances to combustible materials such as walls, floor joists and ceilings. The joint be-
tween the stove flue collar and the stovepipe must also be sealed using the glass fibre rope
provided. It is important that the insulated flue system is properly supported both at ceiling
level and at roof level. THE STOVE MUST NOT BEAR THE WEIGHT OF THE CHIMNEY SYS-
TEM (See chimney manufacturer’s instructions). Excessive weight on the stove will inhibit ex-
pansion and could lead to damage of the stove top. Damage caused to the stove in this way
would not be covered by the manufacturers guarantee.
In the event that a chimney fire occurs resulting from faulty operation or prolonged use of
damp wood fuel, close the air vents completely and contact your local fire department im-
mediately.
How to position the baffle and access baffle
Make sure that the upper baffle plate (2) is located into its cor-
rect position. It should be placed on top of the rear (fixed) baf-
fle section and secured into position against the 2 upstanding
cast lugs. (See diagram).
Note: The access baffle (3) must always be fitted when the
stove is in use, as it not only assists the combustion proc-
ess, but also gives essential protection to the stove’s top
plate.
Be aware of the following:
Cleaning procedure: Discuss this with chimney sweep or qualified installer prior to
or during the stove installation.
Chimney draft: If the chimney draft is naturally poor it is better to install the flue
from the top of the stove so as to minimise any internal resistance of the flue gases.
Avoid having any more than 2 bends in the flue system and limit the length of the
offset between bends.