1.5 The chimney
Only if National or Local Regulations permit are you permitted to connect a stove into a chim-
ney that is shared by another appliance. YOU MUST be aware of any applicable Regulations
in this respect.
The wood-burning stove must never been connected to a chimney to which a gas-burning stove
or appliance is connected.
An efficient modern stove places heavy demands on the chimney, and you should have the
chimney regularly swept and inspected by your approved chimney sweep.
The cross-sectional area of the chimney (at its narrowest point) must comply with National and
Local Building Regulations. Generally, the area needed for a Morsø wood-burning stove instal-
lation should measure at least 175 cm2 (150 mm diameter).
An over-sized chimney is generally hard to keep warm and results in poor draft. In cases where
there is an oversized masonry chimney, it is recommended that the chimney be lined using an
appropriate chimney lining system with the correct internal diameter.
With respect to the chimney termination, all chimneys should terminate in accordance with
National and Local Building Regulations.
Note that National and Local Regulations also apply with regard to the placement of chimneys
and flues in connection with thatched roofs. See the section on Draft Conditions, 1.9.
The chimney or flue system must be equipped with access doors for inspection and cleaning.
The size of the cleaning door in the chimney must at least equal to that of the cross-sectional
area of the chimney.
In the event that a chimney fire occurs resulting from faulty operation or prolonged use
of damp wood fuel, close the air vents completely and contact your local fire department
immediately.
Stoves installed on small craft should use the Morsø canal boat chimney system or meet
the chimney requirements of BS 8511:2010
1.6 Fluepipe connections
The stove is supplied with a factory fitted flue collar (1), this is
fitted to the top plate. A round cast iron blanking plate covers
the rear flue outlet.
When required, the flue collar can be removed and relocated to
the rear flue outlet. Untwist the blanking plate positioned on the
rear flue outlet anticlockwise and remove. The flue collar can
now be clamped into position using the fixing lugs attached.
Make sure that the baffle (2), firebricks, and the riddling grate
are positioned correctly.
1430 corner installation