Installation Guide
Morningstar USB MeterBus Adapter Instructions
The USB MeterBus Adapter (model: UMC-1) converts the Morningstar MeterBus RJ-
11 electrical interface to a standard USB 2.0 interface which allows communication
between a PC and applicable Morningstar charge controllers or inverters *. The
UMC-1 is required for programming custom charging set-points and logging data
using Morningstar’s MSView PC software. The UMC-1 is also required for
communication with any 3
rd
party hardware that supports MODBUS
TM
communication.
* Morningstar controllers or inverters that only have a MeterBus connection , i.e. no
serial or other communications port. This includes the Sunsaver MPPT, SunSaver
DUO, and Suresine products.
Notes:
1) 4-conductor or 6-conductor telephone cord is acceptable
2) The UMC-1 is fully opto-isolated. USB electrical ground
is NOT the same ground as RJ-11 / controller.
Modbus documentation including register locations, scaling, and
definitions can be found on Morningstar’s website at:
www.morningstarcorp.com
MS-001373 04/28/2015DS
USB B to USB A cable
(1 meter, included)
RJ-11 telephone cable
(1 meter, included)
Morningstar Charge Controller or
Inverter
PC or
3
rd
party hardware
Wiring Diagram
UMC-1
LED Indication
IMPORTANT!
No software driver included.
Download the latest USB
driver on our website:
www.morningstarcorp.com/support
OFF: No connection to controller GREEN: Connection OK ORANGE: Communication activity