TS-MPPT-600V-48 Wind charging control Info
9
Morningstar does not currently have a list of turbines or manufacturers that have been verified to operate within the
maximum voltage or power range of TriStar MPPT controllers.
Example System Programming with Logged Data:
Turbine: 1800 Watts max. power; 48V nominal Voltage
Rectifier includes a 120V dump load switch.
Programmed Voltage vs. Power Curve for TriStar MPPT (150V), Model: TS-MPPT-60 Controller:
Figure 6: MSView
TM
; TriStar MPPT (150V) Setup Wizard - Voltage vs Power Setpoints Screen Example
These points will create a Piecewise Linear curve shown in Figure 7.
Please note that for the TriStar MPPT 600V that the input current and power is not calibrated which can throw off
the voltage vs. power curve to operate at higher power levels at lower voltages than it is programmed with. Please
see Appendix: TriStar MPPT 600V Input Power Calibration info for Wind regarding this issue.