TS-MPPT-600V-48 Wind charging control Info
8
a. Enter non-zero, positive values for input Voltage and Power with increasing power as voltage
increases. It cannot be programmed to reduce the power at higher voltage levels.
b. Not all 16 Voltage Power setpoints need to be used with V=0.00; P=0.0 for any unused pairs.
c. The controller can operate above the highest voltage setting. It will continue to operate at the max.
power setting up until the derated power at high voltage range or max. voltage shutoff.
Figure 5: MSView
TM
; TriStar MPPT Setup Wizard - Voltage vs Power Setpoints Screen
3) Proper DIP Switch Settings.
a. DIP Switch 1 activates the Wind Feature. (Voltage vs. Power Curve must be programmed first)
b. The other DIP Switches operate according to the Solar PV Setup instructions.
i. Switch 3 activates the custom settings for the nominal voltage (24V, 36V, 48V, 60V) for the
600V. Switches 2&3 are used to set the nominal voltage (Auto,12,24,48) for the 150V.
ii. Switches 4-6 activate the Battery Voltage Regulation Presets or Custom Settings with 4-6 ON
(UP).
iii. Note that the Battery Voltage Custom Setpoints are always programmed using 12V nominal
voltages. It will be multiplied by 4 for 48V or according to the nominal voltage selected; for
24V(X2), [36V(X3) or 60V(X5) for the 600V].
Many Turbine manufacturers will have Voltage vs. Power curve information available.
Maximum open circuit voltage information may also be available from the manufacturer.