TS-MPPT-600V-48 Specifications
+1-215-321-4457
sales@morningstarcorp.com
www.morningstarcorp.com8 Pheasant Run, Newtown, PA 18940 USA
Electrical
Peak Efciency 97.9%
Maximum Battery Current 60A
Maximum Input Operating Current 15A (self limiting)
Maximum Solar Open Circuit Voltage 600V
Nominal Maximum Operating Power *** 3200Wp, 48 Volt
Nominal System Voltage 48 Vdc custom programmable to
24V, 36V and 60V
Battery Operating Voltage Range 16-72Vdc
PV Input Operating Voltage Range 100V to Voc = 525V
Hydro Input Operating Voltage Range Battery Voltage to 500V
Self-Consumption 1.75 - 2.50W
Transient Surge Protection 4500 Watts/port
Electrical Protections
Input Overload, high voltage
Battery
High voltage, battery sense disconnected, remote
temperature sense disconnected
General
Operation
High temperature, reverse current at night, lightning and
transient surges
Communication
Ports
Ethernet, EIA-485, RS-232, MeterBus,
EMC-1 (optional)
Supported
Protocols
MeterBus, MODBUS RTU, MODBUS
TCP/IP,
HTTP, SNMPv2c (optional), SMTP
Environmental
Ambient Temperature -40 °C to +45 °C
Storage Temperature -55 °C to +85 °C
Humidity 100% non-condensing
Tropicalization
Epoxy encapsulation,
conformal coating,
marine-rated terminals
Battery Charging
Charging Stages
MPPT, absorption, oat,
equalize
Temperature
Compensation
Coefcient: 5mV/°C/cell (25° ref)
Range: 30 °C to +80 °C / -22 °F
to +176 °F
Set points: Absorption, Float,
Equalize, HVD
Note: Remote Temperature Sensor is included.
Mechanical
Dimensions
Standard Version: 39.2 x 22.1 x 14.9 cm / 15.4 x 8.7 x 5.9 in
DB & TR Version: 54.2 x 22.1 x 14.9 cm / 21.4 x 8.7 x 5.9 in
Unit Weight
Standard Version: 9.0 kg / 19.8 lbs
DB & TR Version: 12.8 kg / 28.1 lbs
Maximum Wire
Size
Power Terminals: 2.5 mm - 35 mm / 14 AWG - 2 AWG
RT/Sense Terminals: 0.25 mm - 1.0 mm / 24 AWG - 16
AWG
Conduit
Knockouts
M20; 0.50, 1.00, 1.25 inches
Enclosure Rating Type 1 (indoor and vented), IP20
Technical Specications
Available in four versions:
• TS-MPPT-60-600V-48: Standard
• TS-MPPT-60-600V-48-DB: with Disconnect Box
• TS-MPPT-60-600V-48-DB-TR*: with DC Transfer Switch
• TS-MPPT-60-600V-48-DB-TR-GFPD**: Pre-wired with
Ground Fault Protection Device
Options:
• TriStar 600V Meter (TS-M-2-600V)
• TriStar Remote Meter (TS-RM-2)
• Meter Hub (HUB-1)
• Relay Driver (RD-1)
• 600V Ground Fault Protection Device (GPD-600V)
Certications:
• CE, RoHS, NEC Compliant
• ETL Listed: UL-1741 and Canadian CSA C22.2 No. 107.1.01
• FCC Class B Part 15 Compliant
Warranty: 5 year warranty period. Contact Morningstar
or your authorized distributor for complete terms.
Noteworthy features:
• Accommodates PV systems > 150 Voc with long wire runs from
the array to the controller
• Uses Morningstar’s patented 4-stage charging algorithm to optimize
battery health
• Features extensive system networking, monitoring and communications
• Optimized for harsh environments and equipped with electronic protections
• Enables battery back-up for grid-tied systems using more efcient
DC-coupling system topology (as opposed to AC-coupling typical from
other brands)
* Can be used as 2-pole version of the disconnect box. ** See GFPD -600V datasheet for additional specications. *** Input power can exceed Nominal
Maximum Operating Power, but controller will limit and provide its rated continuous maximum output current into batteries. This will not harm the controller.
Due to Morningstar’s policy of continuous improvement, product availability, features and specications are subject to change without notice.
Revision: Control #MS-001897
Rev 4/21 Copyright 2021