Networking and Communication
5.5 Ethernet
!
CAUTION: Risk of Tampering
The TS-MPPT-600V does not feature built-in network security. It is the responsibility of the user or
network administrator to place the TS-MPPT-600V behind a network rewall to prevent unauthorized
access.
!
PRUDENCE : Risque de tentative d’altération
Le TS-MPPT-600V ne comporte pas de sécurité réseau intégrée. Il incombe à l’utilisateur ou à
l’administrateur du réseau de placer le TS-MPPT-600V derrière un pare-feu réseau an d’empêcher
l’accès non autorisé.
The Ethernet port supports HTTP, MODBUS TCP/IP
TM
, SMTP, and SNMP protocols to provide
a fully web-enabled interface between the TriStar MPPT 600V and a LAN/WAN network or the
internet.
Ethernet connections also provide the communication link between multiple TS-MPPT-600V con-
trollers for synchronous operation. Some of the many features the Ethernet connection provides
include:
• program custom settings with MSView
TM
PC software
• monitor the controller from a web browser
• link up to four controllers for synchronous operation
• modify controller settings from a web browser
• log and monitor the system with MSView
TM
PC software anywhere on the internet
• create custom web pages to show system data
• send an email or text message if a fault, alarm, or user-dened event occurs
• monitor and receive messages on an SNMP network
This section provides a summary of each of the features. For detailed information about Ethernet
connectivity and networking, refer to the “Morningstar Communications Document” at:
http://support.morningstarcorp.com
“What Are You Looking For”: All Documents
“Choose Product”: TS-MPPT 600V
“GO”, and then nd listed Morningstar Communications Document
Network Information
Connect to the TriStar MPPT 600V via an Ethernet network (LAN/WAN) or connect the controller
directly to a PC using an Ethernet cross-over cable. Use CAT-5 or CAT-5e twisted pair Ethernet
cables with RJ-45 connectors. A network diagram for both scenarios is shown in gure 5-3 below.
Ethernet Cross-over
Cable
Figure 5-3. Ethernet network diagrams.
Factory Default Network Settings
DHCP enabled
Live View Web Address http://tsmppt + serial number **
IP 192.168.1.253 (if DHCP is not enabled)
Subnet Mask 255.255.255.0
Gateway 192.168.1.1
Primary DNS Server 169.254.1.1
MODBUS TCP/IP
TM
Port 502
** The Live View web address is unique to each controller. If the TriStar MPPT 600V 600Vserial number is 09501234, then the
Live View address is: http://tsmppt09501234. The Live View address is printed on the serial label on the side of the unit for refer-
ence.
The controller’s MAC Address is located on the serial label on the side of the controller.
Two (2) LEDs on the Ethernet jack indicate link and activity status.
Condition Yellow LED Green LED
Network Connection OK ON OFF
Network Activity ON Blinking
Error OFF ON
Web Pages
Connect the TriStar MPPT 600V controller to the network using an Ethernet cable. Wait 5 to
10 minutes for the controller to connect to the network. Open a web browser on any PC on
the network. Enter the Live View web address in the address bar of the web browser. The
TriStar MPPT 600V main Live View webpage will load. Links are provided to real-time data, his-
tory, and network settings adjustment pages.