TriStar MPPT 600V Installation & Operation Manual
69TriStar MPPT 600V Operator’s Manual
7.3 Removing the Power Stage for Service
Step 1 - Disconnect Power from all sources
All sources of power must be disconnected from the unit before proceeding. Open disconnects
and remove fuses as needed.
Step 2 - Remove the wiring box cover
Remove the four (4) screws that secure the wiring box cover to the wiring box. Set the cover and
screws aside.
Step 3 - Disconnect wiring and remove terminal bridge
Disconnect all power wires, battery sense (if used), remote temperature sensor (if used), and
network cables. Also remove the yellow solar terminal bridge and set it aside.
Step 4 - Remove the mating screws
Two(2)screwssecurethepowerstagetothewiringboxasshowningure7-1.Removeboth
screws using a #2 Philips head screw driver.
Step 5 - Remove the mounting tab (keyhole) screw
Removethekeyholemountingscrewasshowningure7-1.
Step 6 - Separate the power stage from the wiring box
Separate the power stage from the wiring box by gently lifting the power stage away from the
wall (mounting surface). The power stage should slide apart from the wiring box, leaving the wir-
ing box and wiring in tact.
KEYHOLE SCREW
MATING SCREWS
Figure 7-1. Mating screws and keyhole screw locations