Networking and Communication
Custom Settings
The TriStar MPPT Setup Wizard in MSView
TM
provides an interface to adjust all operating param-
eters. Morningstar’s MSView
TM
PC software can connect to any TriStar MPPT 600V on the Eth-
ernet network or through a RS-232 serial connection. Refer to the help documentation included
with MSView
TM
for more information.
Email & SMS Alerts
TheemailandSMSalertsfeaturesendsnoticationtoanemailaddressormobilephoneifone
of the following occurs:
• TriStar MPPT 600V self diagnostics fault condition
• TriStar MPPT 600V self diagnostics alarm condition
• User-denedevent(e.g.batteryvoltageislessthan46Volts)
UptofouremailandSMSalertscanbeconguredfromthenetworksettingswebpageinthe
MSView TriStar MPPT wizard.
View logged data
The TriStar MPPT 600V logs up to 200 days* of daily data. The controller always logs the stan-
dardvalueslistedbelow.UsingMSView,thecontrollercanbeconguredtologadditionaloption-
al values each day. The maximum number of days that can be stored decreases as the number
of logged values increases.
Standard Values
• Minimum Battery Voltage
• Maximum Battery Voltage
• Daily Events (Equalize triggered, Entered Float, Alarm/Fault occurred, Controller Reset)
• Faults / Alarms - recorded only if a fault or alarm occurs that day
Optional Values
• Maximum Array Voltage
• Maximum Power Output
• Charge Amp-hours
• Charge Watt-hours
• Minimum/Maximum Battery Temperature
• Charge stage regulation timers for Absorption, Float, Equalize
* logging only standard values