TriStar MPPT 600V Installation & Operation Manual
26
Installation
Figure 3-13. Removing the EIA-485 socket connector
RS-232 Connection
TheserialRS-232portisastandard9-pin(DB9)femaleconnector.Alow-proleserialconnector
is recommended to save room in the wiring box.
NOTE:
The RS-232 and EIA-485 ports share hardware. Both ports cannot be used simultaneously.
REMARQUE :
Les ports RS-232 et EIA-485 partagent le matériel. Ils ne peuvent pas être utilisés simultanément.
Ethernet Connection
The RJ-45 Ethernet jack features two (2) indicator LEDs for connection status and network traf-
c.UseCAT-5orCAT-5etwistedpaircableandRJ-45plugs.Ifpossible,pullthenetworkcable
through conduit before crimping on the RJ-45 connectors. If using pre-assembled cables, take
care not to damage the plugs when the cables are pulled through conduit.
MeterBus
TM
Connection
MeterBus
TM
networks use standard 4-wire or 6-wire RJ-11 telephone cables. If possible, pull the
telephone cable through conduit before crimping on the RJ-11 connectors. If using pre-assem-
bled cables, take care not to damage the plugs when the cables are pulled through conduit.