Installation Guide

65TriStar MPPT 600V Operator’s Manual
64
Networking and Communication
Custom Settings
The TriStar MPPT 600V 600VSetup Wizard in MSView
TM
provides an interface to adjust all oper-
ating parameters. Morningstar’s MSView
TM
PC software can connect to any TriStar MPPT 600V
on the Ethernet network or through a RS-232 serial connection. Refer to the help documentation
included with MSView
TM
for more information.
Email & SMS Alerts
The email and SMS alerts feature sends notication to an email address or mobile phone if one
of the following occurs:
TriStar MPPT 600V self diagnostics fault condition
TriStar MPPT 600V self diagnostics alarm condition
User-dened event (e.g. battery voltage is less than 46 Volts)
Up to four email and SMS alerts can be congured from the network settings web page in the
MSView TriStar MPPT 600V 600Vwizard.
View Logged Data
The TriStar MPPT 600V logs up to 200 days* of daily data. The controller always logs the stan-
dard values listed below. Using MSView, the controller can be congured to log additional option-
al values each day. The maximum number of days that can be stored decreases as the number
of logged values increases.
Standard Values
Minimum Battery Voltage
Maximum Battery Voltage
Daily Events (Equalize triggered, Entered Float, Alarm/Fault occurred, Controller Reset)
Faults / Alarms - recorded only if a fault or alarm occurs that day
Optional Values
Maximum Array Voltage
Maximum Power Output
Charge Amp-hours
Charge Watt-hours
Minimum/Maximum Battery Temperature
Charge stage regulation timers for Absorption, Float, Equalize
* logging only standard values
NOTE: If an RTS isn't installed, minimum and maximum battery temperatures will not
be available. In this case, minimum/maximum battery temperature will not be logged,
even if selected as an optional variable
SNMP
For telecom and industrial applications that require SNMP monitoring of deployed systems, the
TriStar MPPT 600V 600Vwill behave as an SNMP agent and supports the following commands:
TRAP
GET
GETNEXT
A link to the agent Management Information Base le (*.MIB) is available on the
TriStar MPPT 600V Live View Network Settings page.