TriStar Manual
52
Networking and Communication
Factory Default Network Settings
DHCP enabled
Live View Web Address http://tsmppt + serial number **
IP 192.168.1.253 (if DHCP is not enabled)
Subnet Mask 255.255.255.0
Gateway 192.168.1.1
Primary DNS Server 169.254.1.1
MODBUS TCP/IP
TM
Port 502
** The Live View web address is unique to each controller. If the TriStar MPPT 150V serial number is 09501234, then the Live
View address is: http://tsmppt09501234. The Live View address is printed on the serial label on the side of the unit for reference.
The controller’s MAC Address is located on the serial label on the side of the controller.
Two (2) LEDs on the Ethernet jack indicate link and activity status.
Condition Green LED Yellow LED
Network Connection OK ON OFF
Network Activity ON Blinking
Error OFF ON
Web Pages
Connect the TriStar MPPT 150V controller to the network using an Ethernet cable. Wait 5 to
10 minutes for the controller to connect to the network. Open a web browser on any PC on
the network. Enter the Live View web address in the address bar of the web browser. The
TriStar MPPT 150V main Live View webpage will load. Links are provided to real-time data, his-
tory, and network settings adjustment pages.
Pages served by the TriStar MPPT 150V are ideal for retrieving quick information about the
charge controller and making adjustments to network settings. However, there is no ability to
customize the layout or data displayed. Also, information from multiple controllers cannot be dis-
played on the same webpage.
Custom Settings
The TriStar MPPT 150V Setup Wizard in MSView
TM
provides an interface to adjust all operating
parameters. Morningstar’s MSView
TM
PC software can connect to any TriStar MPPT 150V on the
Ethernet network or through a RS-232 serial connection. Refer to the help documentation includ-
ed with MSView
TM
for more information.