TriStar Manual
47TriStar MPPT Operator’s Manual
5.2 Morningstar MeterBus
TM
Morningstar’s proprietary MeterBus
TM
protocol allows communication between compatible Morn-
ingstar products. Use a MeterBus
TM
network to:
• display net system data for multiple TriStar / TriStar MPPT 150V systems**
• communicate with a TriStar Digital Meter 2 or TriStar Remote Meter 2
• communicate with a Relay Driver or other compatible Morningstar accessories (see sec-
tion 2.5 for more details)
**A Morningstar MeterBus Hub (HUB-1) and either a TriStar Digital Meter 2 (TS-M-2) or TriStar Remote Meter 2 (TS-RM-2) are
required, not included.
A MeterBus Hub (model: HUB-1) is required for MeterBus networks containing multiple
TriStar MPPT 150V controllers. The ports on the hub are electrically isolated to prevent dam-
age in the event of broken grounds or voltage differences between controllers. Figure 5-1 below
shows an example MeterBus
TM
network with two (2) TriStar MPPT 150V controllers and a TriStar
Remote Meter 2 (TS-RM2).
MeterBus
TM
Network Hub
TriStar
Remote Meter
TriStar-MPPT
Controllers
Figure 5-1. An example MeterBus network.
Uptove(5)controllerscanbenetworkedtogetherwithasinglehub.Multiplehubscanbe
daisy-chained together to allow networks of up to 14 controllers and a meter.
Refer to the HUB-1 and TriStar Meter manuals for more information about Morningstar Meter-
Bus
TM
networking.