User manual
6
Removing the Battery Select jumper
2. Select Load Control – Low Voltage Disconnect / Reconnect
Switch 2 OFF (i): LVD = 11.50 V, LVR = 12.60 V
Switch 2 ON (h): LVD = 11.00 V, LVR = 12.10 V
2
2
These values can be modified with custom programming.
3. Enable or Disable Auto-Equalization
Switch 3 OFF (i): Auto-Equalize OFF
Switch 3 ON (h): Auto-Equalize ON
(agm, flooded battery type only)
Every 28 days or if the battery
discharges too low the previous night.
4. Communication – Meter / MODBUS®
Switch 4 OFF (i): Morningstar Remote Meter
Switch 4 ON (h): Modbus® protocol for
MSView, 3rd party devices
2
2
Morningstar PC Meterbus Adapter (Model: MSC) required.
5. Mounting
To mount, mark four mounting holes, drill holes 3/32” (2.5 mm) and
screw controller to surface.