User manual
ENGLISH
15
Battery Setpoints (@ 25°C)
Gel
Sealed
AGM
Flooded
Absorption Voltage 14.0 V 14.1 V 14.3 V 14.4 V
Float Voltage 13.7 V 13.7 V 13.7 V 13.7 V
Time until Float 3 hr 3 hr 3 hr 3 hr
Equalize Voltage N/A N/A 14.5 V 14.9 V
Equalize Duration N/A N/A 3 hrs 3 hrs
Equalize Calendar N/A N/A
28
days
28
days
Max. Regulation Voltage
1
15 V / 30 V
Low Voltage Disconnect
2
11.5 V / 11.0 V
Low Voltage Reconnect
2
12.6 V / 12.1 V
1
Not temperature compensated. 15 V @ 12 V nominal, 30 V @ 24 V
nominal.
2
Adjustable by switch, not temperature compensated. 11.0 V / 12.1 V
setting can be modified in custom settings.
NOTE: Temperature compensation increases regulation
voltage in cold temperature. A 15 V (30 V @ 24 V nominal)
maximum battery voltage limit prevents damage to sensitive
DC loads.
Environmental
Ambient Temperature Range –40°C to +60°C
Storage temperature –55°C to +100°C
Humidity 100% N.C.
Enclosure IPI0 (indoor)