SunSaver MPPT MODBUS Document

TriStar MPPT MODBUS Document v10
http://www.morningstarcorp.com 9/26 05 Dec 2011
Filtered ADC
Vb
[25][0x0018] (V). battery voltage, filtered.
Battery voltage used for regulation by the TS-MPPT. This voltage will be the same as the Battery Sense
voltage if the sense connections are connected and valid. Otherwise, this value is the same as Vb_term
voltage.
Vb_term
[26][0x0019] (V). battery terminal voltage, filtered.
Voltage measured directly at the battery power connections on the TriStar MPPT.
Vb_sense
[27][0x001A] (V). battery sense voltage, filtered.
Voltage measured by the Battery Sense connections on the TriStar MPPT.
Va
[28][0x001B] (V). solar input voltage, filtered.
Va is the terminal voltage of the solar input connection.
Ib
[29][0x001C] (A). battery charge current, filtered.
Charging current to the battery as measured by on-board shunts.
Ia
[30][0x001D] (A). solar input current, filtered.
Input current from the solar array.
NOTE: Input current is not measured by precision shunts and may differ from the actual input current by
+/- 20%.
Vp12
[31][0x001E] (V). 12 volt supply.
12 Volt power supply voltage.
Vp3
[32][0x001F] (V). 3 volt supply.
3 Volt power supply voltage.