Etmr_eqcalendar
[57484][0xE08B](V). Equalize calendar timer
Number of days since last equalize.
Etmr_batt_service
[57485][0xE08C](days). days since last battery service
Reports the number of days since the last battery service reminder.
Eserial
[57537-57540][0xE0C0 – 0xE0C3](ASCII). Controller serial number
ASCII string of characters that represents the serial number.
Example serial number: 01234567
0xE0C0 = 0x3130 [1][0]
0xE0C1 = 0x3332 [3][2]
0xE0C2 = 0x3534 [5][4]
0xE0C3 = 0x3736 [7][6]
Emodel
[57548][0xE0CC](). Controller model flag.
0 = TSMPPT-45, 1=TSMPPT-60
Ehw_version
[57549][0xE0CD](). Hardware version.
Not ASCII. Major version stored in upper byte, minor version stored in lower byte.
0xE0CD = 0x0102 HW version: 1.2