Evb_ref_lim
[57361][0xE010](V) Maximum regulation limit
An absolute limit on the battery regulation voltage. This is not a temperature compensated value.
Protects high voltage sensitive system loads. Set to zero to disable.
ETb_max
[57362][0xE011](C) Maximum temperature compensation limit
Maximum temperature to clamp temperature compensation.
ETb_min
[57363][0xE012](C) Minimum temperature compensation limit
Maximum temperature to clamp temperature compensation.
EV_soc_g_gy
[57366][0xE015](V). green to green/yellow limit
LED transition setpoint. Specifies the battery voltage at which the LED state will change from Green to
Green/Yellow.
EV_soc_gy_y
[57367][0xE016](V). LED Green/Yellow to Yellow limit
LED transition setpoint. Specifies the battery threshold voltage at which the LEDs will change from
green/yellow to yellow indication.
EV_soc_y_yr
[57368][0xE017](V). LED Yellow to Yellow/Red limit
LED transition setpoint. Specifies the battery threshold voltage at which the LEDs will change from
Yellow to Yellow/Red indication.
EV_soc_yr_r
[57369][0xE018](V). LED Yellow/Red to Red limit
LED transition setpoint. Specifies the battery threshold voltage at which the LEDs will change from
Yellow/Red to Red indication.
Emodbus _id
[57370][0xE019](). MODBUS ID