SunSaver MPPT Installation and Operation Manual

MORNINGSTAR CORPORATION 7
1.0
Installation Safety Precautions
WARNING:
This unit is not provided with a GFDI device. This
charge controller must be used with an external
GFDI device as required by the Article 690 of
the National Electrical Code for the installation
location.
Mount the SunSaver-MPPT indoors. Prevent exposure to the
elements and do not allow water to enter the controller.
Install the SunSaver in a location that prevents casual contact.
The SunSaver heatsink can become very hot during operation.
Use insulated tools when working with batteries.
Avoid wearing jewelry during installation.
The battery bank must be comprised of batteries of same type,
make, and age.
Do not smoke in the vicinity of the battery bank.
Mount the controller at least 3 ft (1 m) away from vented bat-
teries unless separated by a barrier or located in a separate
compartment.
Power connections must remain tight to avoid excessive heating
from a loose connection.
Use properly sized conductors and circuit interrupters.
This charge controller is to be connected to DC circuits only.
These DC connections are identied by the symbol below.
Direct Current Symbol