SunSaver MPPT Installation and Operation Manual
MORNINGSTAR CORPORATION 41
5.0
5.0 Troubleshooting
5.1 Error Indications
NOTE: If an optional Morningstar Remote Meter is
attached to the SunSaver MPPT , use the self-diagnostic
feature to determine the cause of the error indication.
Refer to the Remote Meter Operator’s Manual for more
information.
Status LED Error Indications
• PV High Voltage Disconnect Flashing Red
• RTS Shorted Flashing Red
• RTS Disconnected Flashing Red
• Damaged local temp. sensor Solid Red
1
• Damaged heatsink temp. sensor Solid Red
1
• Damaged input MOSFETs Solid Red
1
• Firmware Error Solid Red
1
1 - heartbeat indication flickers the Status LED off briefly every 5 seconds
Battery Status LED Error Indications
• Load High Voltage Disconnect R-G Sequencing
• High Temperature Disconnect R-Y Sequencing
• Remote Temp. Sensor Error Y/R - G/Y Sequencing
• External Wiring Error G/R-Y Sequencing
• Load Overcurrent Y/R-G Sequencing
• Load Short Circuit G/R-Y Sequencing
• Custom Setpoints Update G/Y/R Flashing
• Self-test Error R-Y-G Sequencing