SunSaver MPPT Installation and Operation Manual
MORNINGSTAR CORPORATION 17
3.0
Figure 2. Removing the Battery Select jumper.
Load Control – Low Voltage Disconnect / Reconnect
Choose between two (2) load control Low Voltage Discon-
nect / Reconnect settings.
SWITCH 2 OFF (↓): LVD = 11.50 V, LVR = 12.60 V
SWITCH 2 ON (↑): LVD = 11.00 V, LVR = 12.10 V
2
(2) These values can be modified with custom programming. See Section 4.7
Programming Custom Setpoints for more information.
Enable or Disable Auto-Equalization
Turn the auto-equalize feature OFF or ON. The auto-
equalize feature will administer an equalization charge
(ooded battery type only) every 28 days or if the battery
discharges too low the previous night. There is no
equalization charge for the gel or sealed battery type.
SWITCH 3 OFF (↓): AUTO-EQUALIZE OFF
SWITCH 3 ON (↑): AUTO-EQUALIZE ON
(agm, ooded battery type only)