SunSaver MPPT Installation and Operation Manual

3.0 INSTALLATION INSTRUCTIONS
3.2 Conguration
The four (4) Settings Switches and the Battery Select
Jumper adjust the SS-MPPT battery type, load control,
equalization, and communication settings. This section
details the conguration for each setting.
Select a Battery Type
The SS-MPPT provides four (4) different battery types
as shown in table 1 below. Use Settings Switch 1 and the
Battery Select Jumper to choose the battery type. See
Section 7.0 Technical Specications for detailed charging
information for each battery type.
The battery select jumper is secured in the terminal block
between terminal #6 and terminal #7 as shown in gure 2.
The second column in table 1 species whether the jumper
should be removed or remain in place, depending on the
desired battery type.
Battery Type Battery Jumper Switch 1
Gel
1
INSERTED ON (↑)
Sealed INSERTED OFF (↓)
AGM
1
REMOVED ON (↑)
Flooded REMOVED OFF (↓)
(1) Setpoints for this battery type can be modified with custom program-
ming. See Section 4.7 Programming Custom Setpoints for more informa-
tion.
Table 1. Battery Type selection