SunSaver MPPT Installation and Operation Manual

MORNINGSTAR CORPORATION 15
3.0
3.0 Installation Instructions
3.1 General Installation Notes
Read through the entire installation section rst before
beginning installation.
Be very careful when working with batteries. Wear
eye protection. Have fresh water available to wash
and clean any contact with battery acid.
Use insulated tools and avoid placing metal objects
near the batteries.
Explosive battery gasses may be present during
charging. Be certain there is sufcient ventilation to
release the gasses.
Do not install in locations where water can enter the
controller.
Loose power connections and/or corroded wires
may result in resistive connections that melt wire
insulation, burn surrounding materials, or even cause
re. Ensure tight connections and use cable clamps
to secure cables and prevent them from swaying in
mobile applications.
Only charge lead-acid or NiCd batteries.
The SunSaver MPPT Battery connection may be
wired to one battery or a bank of batteries. The fol-
lowing instructions refer to a singular battery, but it
is implied that the battery connection can be made
to either one battery or a group of batteries in a bat-
tery bank.