SunSaver MODBUS Specifications

Setpoint at which the loads will reconnect after a high voltage condition.
ER_icomp
[57383][0xE026](V/A). LVD Load current compensation
The LVD setpoint can be compensated in proportion to load current, lowering the disconnect value
when the battery is under load. Note that the LED setpoints are also compensated accordingly.
Et_lvd_warn
[57384][0xE027](sec). LVD warning timeout
Defines the period of time to wait before disconnecting the loads, once battery voltage has dropped to
the Low Voltage Disconnect setpoint.
Miscellaneous Settings
EV_soc_g_gy
[57372][0xE01B](V). green to green/yellow limit
LED transition setpoint. Specifies the battery voltage at which the LED state will change from Green to
Green/Yellow.
EV_soc_y2g
[57393][0xE030](V). LED Yellow to Green limit (rising voltage)
LED transition setpoint. Specifies the battery threshold voltage at which the LEDs will change from
yellow to Green indication.
EV_soc_g2y
[57394][0xE031](V). LED Green to Yellow limit (falling voltage)
LED transition setpoint. Specifies the battery threshold voltage at which the LEDs will change from
Green to Yellow indication.
EV_soc_y2r0
[57395][0xE032](V). LED Yellow to Blinking Red limit (falling voltage)
LED transition setpoint. Specifies the battery threshold voltage at which the LEDs will change from
Yellow to Blinking Red indication.
EV_soc_r2y
[57396][0xE033](V). LED Red to Yellow limit (rising voltage)