SunSaver MODBUS Specifications
EV_hvr
[57373][0xE01C](V) High Voltage Reconnect
The HVD fault/alarm will be cleared once the battery voltage drops below this setpoint.
Evb_ref_lim
[57374][0xE01D](V) Maximum regulation limit
An absolute limit on the battery regulation voltage. This is not a temperature compensated value.
Protects high voltage sensitive system loads. Set to zero to disable.
ETb_max
[57375][0xE01E](C) Maximum temperature compensation limit
Maximum temperature to clamp temperature compensation.
ETb_min
[57376][0xE01F](C) Minimum temperature compensation limit
Maximum temperature to clamp temperature compensation.
Load Mode
EV_lvd
[57379][0xE022](V). Low Voltage Disconnect
Setpoint to determine the load turn off voltage. When the battery has discharged too far, the load should
be turned off to prevent over-discharge of the battery.
EV_lvr
[57380][0xE023](V). Low Voltage Reconnect
Battery setpoint that determines when the load will be reconnected. After the battery recharges to this
setpoint, the load will be reconnected.
EV_lhvd
[57381][0xE024](V). Load High Voltage Disconnect
Disconnect the loads if the battery voltage rises too high. This function can protect DC loads that are
sensitive to high input voltage.
Set to zero to disable HVD
EV_lhvr
[57382][0xE025](V). Load High Voltage Reconnect