SunSaver MODBUS Specifications
EEPROM Values
EEPROM values that require updating are done so once every 24 hours.
Charging Settings (bank 1 & bank 2)
Diagram A Charging stages and defining variables.
EV_reg [57345][0xE000](V). Regulation voltage (absorption), bank 1 @ 25ºC.
EV_reg2 [57558][0xE00D](V). Regulation voltage (absorption), bank 2 @ 25ºC.
The battery will charge at 100% charge current until battery voltage reaches this setpoint. The controller
will begin to taper input current so that this setpoint is maintained, but not exceeded. See diagram A.