IMPORTANT: This is not intended to be a complete system diagram; fusing, discon-
nects, and grounding should comply with local electric codes.
Notes:
Two (or more) Morningstar charge controllers can be paralleled to charge the same battery bank.•
For best performance:•
Each controller should be connected to its own solar array1.
Each controller should be set to the same charging program/setting2.
If an RTS (Remote Temperature Sensor) is to be used, each controller must have its own RTS 3.
(temperature sensors cannot be shared between controllers)
If the controller(s) has a Battery Sense connection, install Battery Voltage Sensing wires so 4.
that battery voltage is measured accurately across all controllers.
The diagram can be applied to any Morningstar controllers.•
For detailed installation information, please consult the respective product manuals.•
+ -
PV Array
Batt
Bank
+
-
SunSaver Controller
SunSaver Controller
Load
Battery +
Battery +
Battery -
Battery -
Array 2 +
Array 2 -
GND
+ -
PV Array
Array 1 +
Array 1 -
Load -
Load +