User manual

D) A new set of custom controller settings will appear populated with default values. Click
Next> 4 successive times, leaving all default charging settings unchanged for each page.
IMPORTANT: This guide only addresses Lighting Control and does not cover adjustment of other custom param-
eters such as charge settings and load low voltage disconnect settings. For more info on these, please refer to the
MSView Help File, found under the Help menu -> Help Topics in MSView.
E) You should now be looking at the Lighting Mode - Timers conguration screen. Two
clock graphs are provided; the left shows each of the 4 individual timing channels while
the right shows the combination of all 4 channel timers. The 4 channels combine to create
the total load functionality displayed by the right clock graph. For each of the clock graphs,
the green shaded areas indicate times of the day when the load will be powered.
STEP 3: Adjust Lighting/Load Timing
IMPORTANT: This section explains the procedure for conguring Dusk-to-Dawn lighting control (lights/load on at
sundown, remain on throughout the night, off at sunrise, remain off throughout the daylight hours). Other example
timing schemes are explained in detail in Appendix I.
A) Channel data will initially be ‘greyed-out’ and uneditable. Click the Enable Lighting
checkbox. Channel data should now be editable.
page 6 of 18