Installation manual
© 2014 EcoInnovation Ltd (NZ) Page 97
8.3.3. Pelton (PLT) turbine assembly
Turbine arrives fully assembled, other than the jet holders. This exploded diagram will assist
you once it comes time to service the turbine.
It would be prudent for the installer to remove the PMA and check that all connections are
tight and familiarise themselves with the product so the can quickly service it in the future.
Installing jet assemblies
It may be necessary (depending on the PLT model) to
remove the Pelton runner in order to install the jet
assembly as shown. If so then follow the procedure
below in reverse order. The PVC jet sleeve is mounted
inside the turbine with the PVC ball valve on the outside.
Note that there is also a Jet ‘O’ ring that fits on the jet
sleeve thread after being inserted through the casing.
This ‘O’ ring ensures that the valve and jet sleeve seals
onto the casing and does not leak. The ‘O’ ring is on the
outside of the casing. Grease all threads.
Installing the Pelton runner
Ensure that when you mount the Pelton runner you fit it the correct way round. The water jet
should hit the splitter (the straight knife edge) of the Pelton spoons.
Jet assembly in position