Installation manual

© 2014 EcoInnovation Ltd (NZ) Page 47
hence the cost of the cable). Changing the "design load voltage" will also have a dramatic
effect, which may lead you to choose an MPPT controller for sites with long cables.
Try to keep losses as low as possible, particularly if you have limited hydro generation and
need all the power you can get. A loss of 5% in cables is normal. Cables with losses greater
than 10% should only be used in cases where the cable cost is very significant in the total
equipment cost and/or where you can generate plenty of power (more than needed).
Be warned that high cable losses may cause nuisance triggering of any Klampits fitted in
your turbine.
5.5. Charge controller choice
A vital part of battery systems is the charge controller. This device protects the battery by
regulating the current fed into it, so as to limit the rising battery voltage to a particular
maximum limit. This "set-point" is automatically chosen for the battery type and temperature
and its state of charge. There are two types of controller to choose from:
5.5.1. Diversion load controllers
PWM (Pulse Width Modulation) diversion load controllers are needed when the turbine is
connected directly to the battery. They work by diverting excess current into a heating load
known as a "diversion load" or "dump load". More details follow in the next section.
Pros and cons of diversion load controllers versus MPPT controllers:
Pros:
Lower cost
Simpler wiring at safer voltages with fewer things to go wrong
Provides useful heating output for hot water etc.
Internal losses are low <1%
Displays how much energy it has dumped on a screen in some cases
Cons:
Turbine runs at battery voltage, so manual turbine rpm optimisation is often needed
Hydro rpm can never be perfectly optimised as it varies with the battery voltage
Direct connection of turbine to battery does not fail safe; failure of the PWM controller or
attached element can result in severe overcharging of your battery bank or complete
flattening and damage (resistive element locks on). MPPT regulation generally fails safe
but costs a little more. As the battery bank is often the most expensive part of the
system, you need to carefully consider if the small saving is worth the risk.
PWM type diversion controllers and their heating loads can make a significant buzzing
noise that might be unwelcome in a living space.