Installation manual
© 2014 EcoInnovation Ltd (NZ) Page 121
11.3. Hydro installations with room for improvement
This example has a few issues which could have
been avoided:
The turbine is difficult to access for servicing
With the door closed, the humidity in this
plastic enclosure can get very high. If you do
this ensure good ventilation to outside air.
Plastic PVC pipe work could be tidier with
fewer bends
This example shows the turbine and inverter enclosed
in same structure. If you do this you should ensure:
Ease of removal for servicing
Good ventilation to limit humidity
Do not confuse AC and DC wiring runs when you order
your turbine.
On this site we were advised of a long cable DC run, but
it was installed on a long AC cable into the grid.
DC lines can have losses from 0-10% and higher in
some cases. AC cables need to be run with much less
loss or the inverter may trip, causing a nuisance. Always
follow recommended wiring sizes in your inverter
installation manual for grid connected inverters.