FM60 tends to track down from the Voc and MC250 (in hydro mode) tends to track up from
the battery voltage. Once it gets to about 80 VDC input it will also have 1.6kW on the
display.
For more detailed information on the set up of FM60/FM80 , MC150/200/250, MC KID and
other makes of MPPT controllers refer to the new 2014 Technical Manual.
8.4.5. Visual optimization of PLT turbines
Once optimisation of PLT turbines is
complete, the turbine exhaust water
should be hitting the clear glazing at 90
degrees to the jet.
If the exhaust water bounces back
towards the jet then the turbine is
running too slow and you should pack
the magnetic rotor more (or raise the
MPPT voltage).
If the exhaust water travels through and
hits the opposite side of the casing then
the turbine is running too fast and you
should reduce the packing (or lower the
MPPT voltage).
Too slow Good Too fast
Top and bottom jet exhaust water is bouncing back
towards the jet, indicating turbine is running slow. A
little more magnetic rotor packing is needed.