58 Specifi cations
8.0 Specifi cations
Electrical
TS-MPPT-45 TS-MPPT-60
Nominal System Voltage 12, 24, 36, or 48 Volts dc
Maximum Battery Current 45 Amps 60 Amps
Maximum Solar Input Voltage 150 Volts dc
Battery Operating Voltage Range 8 - 72 Volts dc
Nominal Maximum Input Power:
12 Volt 600 Watts 800 Watts
24 Volt 1200 Watts 1600 Watts
48 Volt 2400 Watts 3200 Watts
Voltage Accuracy 12 / 24 V: ≤ 0.1 % ± 50 mV
48 V: ≤ 0.1 % ± 100 mV
Self consumption (tare loss) 1.3 - 2.7 Watts
Transient Surge Protection 4500 Watts / port
Battery Charging
Charging algorithm 4 - stage
Charging stages Bulk, Absorption, Float, Equalize
Temperature compensation coeffi cient -5 mV / °C / cell (25 °C ref.)
Temperature compensation range -30 °C to +80 °C
Temperature compensated setpoints Absorption, Float, Equalize, HVD
Charging Setpoints:
Settings
Switches
Battery
Type
Absorp.
Stage
Float
Stage
Equalize
Stage
Absorp.
Time
Equalize
Time
Equalize
Timeout
Equalize
Interval
sw: 4-5-6 Volts Volts Volts Minutes Minutes Minutes Days
off-off-off 1 - Sealed* 14.00 13.70 150
off-off-on 2 - Sealed* 14.15 13.70 14.40 150 60 120 28
off-on-off 3 - Sealed* 14.30 13.70 14.60 150 60 120 28
off-on-on 4 - AGM/Flooded 14.40 13.70 15.10 180 120 180 28
on-off-off 5 - Flooded 14.60 13.50 15.30 180 120 180 28
on-off-on 6 - Flooded 14.70 13.50 15.40 180 180 240 28
on-on-off 7 - L-16 15.40 13.40 16.00 180 180 240 14
on-on-on 8 - Custom Custom Custom Custom Custom Custom Custom Custom
* “Sealed” battery type includes gel and AGM batteries
See section X.X for more information
NOTE:
All charging voltage setpoints listed are for 12 Volt systems.
Multiply 2X for 24 Volt systems, 4X for 48 Volt systems.