User manual

5TriStar MPPT Operator’s Manual
Installation Safety Precautions
WARNING:
This unit is not provided with a GFDI device. This charge controller must be used with an
external GFDI device as required by the Article 690 of the National Electrical Code for
the installation location.
Mount the TriStar MPPT indoors. Prevent exposure to the elements and do not allow wa-
ter to enter the controller.
Use insulated tools when working with batteries.
Avoid wearing jewelry during installation.
The battery bank must be comprised of batteries of same type, make, and age.
Do not smoke in the vicinity of the battery bank.
Power connections must remain tight to avoid excessive heating from a loose connection.
Use properly sized conductors and circuit interrupters.
The grounding terminal is located in the wiring compartment and is identi ed by the sym-
bol below.
Ground Symbol
This charge controller is to be connected to DC circuits only. These DC connections are
identi ed by the symbol below.
Direct Current Symbol